Tank / separator

MEP-TANK

Description

  • Separator or tank in the drainage system.
  • Grease or oil separator.

Modelling guidelines

  • Model as an equipment object with size and location.
  • Assign to the matching storey and technical or use zone.

Attributes

Name Description Unit
PredefinedType

Kind of equipment or terminal.

Allowed values

  • STORAGE - storage
  • PRESSUREVESSEL - pressure vessel
  • EXPANSION - expansion
  • VESSEL - vessel
  • BREAKPRESSURE - break pressure
  • FEEDANDEXPANSION - feed and expansion
  • OILSTORAGE - oil storage
Tag

Plant identification (AKS) according to the client standard.

If no project-specific standard exists, suggestion: {Building}-{Storey}-{Trade}-{Plant type}-{nnn} (e.g. B01-02-H-RLT-003).

WarrantyEndDate

Pset_Warranty

Warranty end date - to be provided by the contractor.

DatasheetLink

ePset_ProductData

Link (URI) to the product datasheet.

Status

Pset_TankTypeCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Contact

abstract ag