← All use cases

Pipe (schematic)

MEP-SCH-PIPE

Schematic pipe for early coordination - medium in Reference.

Description

  • Simplified segment or volume for main routes (heating, cooling, water, wastewater, etc.).
  • Used for feasibility and clash checking, not for execution planning.

Modelling guidelines

  • Model as a volume or simplified segment; cross-section according to the sketch concept.
  • Set the medium in Reference (e.g. HZ, KZ, TW, AW, FL).
  • Do not model fittings, control valves, or connection details.

Attributes

Name Description Unit
Reference

Pset_PipeSegmentTypeCommon

Medium of the schematic pipe.

Allowed values

  • HZ - heating
  • VL-H - heating flow (supply)
  • RL-H - heating return
  • KZ - cooling
  • VL-K - cooling flow (supply)
  • RL-K - cooling return
  • TW - drinking water
  • FW - fresh water
  • AW - wastewater (sanitary)
  • WW - wastewater (alternate code)
  • ENT - drainage (building)
  • FL - downpipe (rainwater)
GrossCrossSectionArea

Qto_PipeSegmentBaseQuantities

Cross-sectional area of the modelled schematic pipe.

Status

Pset_PipeSegmentTypeCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel