← All use cases

Doors

DOOR

Walk-through openings in the building envelope and between rooms.

Description

  • Doors, gates, and inspection openings.

Modelling guidelines

  • Glazed areas with a transparent material.
  • Use an IfcMaterial that corresponds to the actual material class.

Attributes

Name Description Unit
GlobalId

Unique IFC GUID of the door element.

PredefinedType

Kind of door.

Allowed values

  • DOOR - door
  • GATE - gate
  • TRAPDOOR - trapdoor
ObjectType

Kind of door.

Allowed values

  • DOOR - door
  • GATE - gate
  • TRAPDOOR - trapdoor

Note

  • IFC2x3 substitute for PredefinedType.
Reference

Pset_DoorCommon

Door reference used for coordination.

IsExternal

Pset_DoorCommon

Indicates whether the door faces the exterior or between interior spaces.

Allowed values

  • TRUE - exterior door
  • FALSE - interior door
Status

Pset_DoorCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
FireRating

Pset_DoorCommon

Fire resistance class of the door according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
AcousticRating

Pset_DoorCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

Area

Qto_DoorBaseQuantities

Area of the door opening.

OverallWidth

Clear width of the door opening.

m
OverallHeight

Clear height of the door opening.

m
OperationType

Door opening type and direction.

Allowed values

  • SINGLE_SWING_LEFT - single swing, hinge left
  • SINGLE_SWING_RIGHT - single swing, hinge right
  • DOUBLE_DOOR_SINGLE_SWING - double door, same swing
  • DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_LEFT - double door, opposite swing, left
  • DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_RIGHT - double door, opposite swing, right
  • DOUBLE_SWING_LEFT - double swing, left
  • DOUBLE_SWING_RIGHT - double swing, right
  • DOUBLE_DOOR_DOUBLE_SWING - double door, double swing
  • SLIDING_TO_LEFT - sliding to left
  • SLIDING_TO_RIGHT - sliding to right
  • DOUBLE_DOOR_SLIDING - double sliding door
  • FOLDING_TO_LEFT - folding to left
  • FOLDING_TO_RIGHT - folding to right
  • DOUBLE_DOOR_FOLDING - double folding door
  • REVOLVING - revolving
  • ROLLINGUP - rolling shutter
  • SWING_FIXED_LEFT - swing fixed left
  • SWING_FIXED_RIGHT - swing fixed right
  • USERDEFINED - user-defined
  • NOTDEFINED - not defined
Name

Door number according to office standard. Recommendation: T{room number of the space the door opens into}. This requires outdoor spaces to receive a room number as well.

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel