← All use cases

Exterior wall

ARC-WALL-EXT

Exterior wall as building envelope - modelled in early phases and for simple facades as a multi-layer component.

Description

  • Load-bearing or non-load-bearing exterior wall with full facade build-up.
  • Used for quantity take-off, building physics, and envelope coordination.

Modelling guidelines

  • In early phases and for simple facades, model as a multi-layer component with full build-up.
  • Model storey by storey; split at component and storey boundaries.
  • When complexity increases or tool limits apply, model the facade build-up as a separate layer.
  • Use an IfcMaterial that corresponds to the actual material class.

Attributes

Name Description Unit
ObjectType

Kind of exterior wall.

Allowed values

  • STANDARD - standard wall
  • PARTITIONING - partition wall
  • SOLIDWALL - solid wall
  • ELEMENTEDWALL - elemented wall
  • MOVABLE - movable wall
  • PLUMBINGWALL - plumbing wall
IsExternal

Pset_WallCommon

Marks an exterior wall.

Allowed values

  • TRUE - exterior wall
Reference

Pset_WallCommon

Facade build-up according to the component catalogue (multi-layer component).

Status

Pset_WallCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
PredefinedType

Kind of exterior wall.

Allowed values

  • STANDARD - standard wall
  • PARTITIONING - partition wall
  • SOLIDWALL - solid wall
  • ELEMENTEDWALL - elemented wall
  • MOVABLE - movable wall
  • PLUMBINGWALL - plumbing wall
FireRating

Pset_WallCommon

Fire resistance class of the exterior wall according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
AcousticRating

Pset_WallCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

NetSideArea

Qto_WallBaseQuantities

Net side area of the modelled exterior wall.

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel