← All use cases

Floor slab (Rough)

ARC-SLAB-FLOOR

Rough dimensions according to structural engineering for floor slabs in design development and permitting stages.

Description

  • Coarsely dimensioned floor slab according to the structural concept.
  • Used for coordination between architecture and structural engineering, not for execution planning.

Modelling guidelines

  • Model as a simplified volume without layer build-up; split at component boundaries.
  • Do not model reinforcement, openings, or detail connections.
  • Early: concept via sketches as structural sketch in the architecture model; verify exclusion zones from the structural engineer.
  • Later: align the same components with Reference in the structural model as well.
  • Use an IfcMaterial that corresponds to the actual material class.

Attributes

Name Description Unit
ObjectType

Marks the floor slab.

Allowed values

  • FLOOR - floor slab
PredefinedType

Marks the floor slab.

Allowed values

  • FLOOR - floor slab
Name

Slab designation according to the structural plan.

Reference

Pset_SlabCommon

Reference used for identification in the coordination model.

LoadBearing

Pset_SlabCommon

Marks the element as a load-bearing component in the architecture model.

Allowed values

  • TRUE - load-bearing element
GrossVolume

Qto_SlabBaseQuantities

Gross volume of the modelled slab.

Status

Pset_SlabCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
FireRating

Pset_SlabCommon

Fire resistance class of the floor slab according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
AcousticRating

Pset_SlabCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.