← All use cases

Column (Rough)

ARC-COLUMN

Rough dimensions according to structural engineering for columns in design development and permitting stages.

Description

  • Coarsely dimensioned column according to the structural concept.
  • Used for coordination between architecture and structural engineering, not for execution planning.

Modelling guidelines

  • Model storey by storey; dimensions according to the structural sketch.
  • Set LoadBearing=TRUE; model as a simplified volume without reinforcement or detail connections.
  • Early: concept via sketches as structural sketch in the architecture model; verify exclusion zones from the structural engineer.
  • Later: align the same components with Reference in the structural model as well.
  • Use an IfcMaterial that corresponds to the actual material class.

Attributes

Name Description Unit
ObjectType

Kind of column.

Allowed values

  • COLUMN - column
  • PILASTER - pilaster (flat column engaged with a wall)
Name

Column designation according to the structural plan.

Reference

Pset_ColumnCommon

Reference used for identification in the coordination model.

LoadBearing

Pset_ColumnCommon

Marks the column as a load-bearing element in the architecture model.

Allowed values

  • TRUE - load-bearing element
GrossVolume

Qto_ColumnBaseQuantities

Gross volume of the modelled column.

Status

Pset_ColumnCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
PredefinedType

Kind of column.

Allowed values

  • COLUMN - column
  • PILASTER - pilaster (flat column engaged with a wall)
FireRating

Pset_ColumnCommon

Fire resistance class of the column according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel